Flexible PID
Up to 20 built-in PID loops, including internal auto-tune, ramp-soak programmer and bumpless transfer. Use Vision570™ PID loops to control temperature, level, and pressure, while the color touchscreen displays data, color trend graphs, and red, attention-grabbing alarm screens.
Data Tables
Data Tables
Use Vision’s smart data tables (120K dynamic data and 192K fixed data), for datalogging and production recipes programs.
Easy Scrolling between Recipes
Easy Scrolling between Recipes
Simply scroll between pre-programmed recipes or menus, using pre-programmed touchkeys. This enables you to choose and activate a desired task via the HMI - immediately, on-site.
Image library
Image library
Easily design your graphic displays using the Vision’s extensive image library.
Time-based Control
Time-based Control
Do you need a specific task to be performed at a specific time and date? Simply mark the hour, date or weekday in the PLC software—and you have created time-based control in 3 clicks.
Information Mode
Monday, June 28, 2010
COM Port -3
Unitronics
3/05 V200- 19- ET 1 Ethernet COM Port
Wiring
Do not touch live wires.
Unused pins should not be connected. Ignoring this directive may damage the
device.
Double-check all wiring before turning on the power supply.
Ethernet Wiring—General
Use CAT5 STP (shielded twisted pair) cable.
Set up the network in accordance with the star configuration shown below.
RJ45 Connector Pin-out
Pin Number Function
1 T+ = Positive transmit signal
2 T- = Negative transmit signal
3 R+ = Positive receive signal
6 R- = Negative receive signal
Topology
Star topology is recommended.
Unitronics 3
V200- 19- ET 1 3/05
Ethernet COM Port
Ethernet Connections
Controller to hub/switch connection Controller to controller connection
Controller Hub/Switch Controller Controller
Pin # Function Pin # Function Pin # Function Pin # Function
1 T+ 1 T+ 1 T+ 3 R+
2 T- 2 T- 2 T- 6 R-
3 R+ 3 R+ 3 R+ 1 T+
6 R- 6 R- 6 R- 2 T-
:
V200-19-ET1 Technical Specifications
Transmission speed 10/100Mbps
Star, based on external hub/switch
Network topology
Category 5 STP (shielded twisted pair) is recommended;
Cable type
UTP (unshielded twisted pair) may also be used
RJ45
Connector type
Up to 100 meters, controller to hub/switch or controller to controller.
Drop line length
5408-0171-6
Unitronics
3/05 V200- 19- ET 1 Ethernet COM Port
Wiring
Do not touch live wires.
Unused pins should not be connected. Ignoring this directive may damage the
device.
Double-check all wiring before turning on the power supply.
Ethernet Wiring—General
Use CAT5 STP (shielded twisted pair) cable.
Set up the network in accordance with the star configuration shown below.
RJ45 Connector Pin-out
Pin Number Function
1 T+ = Positive transmit signal
2 T- = Negative transmit signal
3 R+ = Positive receive signal
6 R- = Negative receive signal
Topology
Star topology is recommended.
Unitronics 3
V200- 19- ET 1 3/05
Ethernet COM Port
Ethernet Connections
Controller to hub/switch connection Controller to controller connection
Controller Hub/Switch Controller Controller
Pin # Function Pin # Function Pin # Function Pin # Function
1 T+ 1 T+ 1 T+ 3 R+
2 T- 2 T- 2 T- 6 R-
3 R+ 3 R+ 3 R+ 1 T+
6 R- 6 R- 6 R- 2 T-
:
V200-19-ET1 Technical Specifications
Transmission speed 10/100Mbps
Star, based on external hub/switch
Network topology
Category 5 STP (shielded twisted pair) is recommended;
Cable type
UTP (unshielded twisted pair) may also be used
RJ45
Connector type
Up to 100 meters, controller to hub/switch or controller to controller.
Drop line length
5408-0171-6
Unitronics
COM Port -2
Unitronics 1
V200- 19- ET 1 3/05
Ethernet COM Port
Installation Instructions
1. Turn power off before opening the
controller.
2. If the controller has an installed Snap-in
I/O module, remove it. Instructions are
given in ‘Removing a Snap-in Module’ in
Slots
the Vision User Guide.
3. Open the OPLC by inserting a screwdriver
into the slots located on the sides of the
controller as shown, then carefully prying
the cover off.
4. The port’s location is covered by plastic.
Port, Remove the plastic covering using a razor
Tabs
covered cutter to cut through the tabs shown in
Figure 1.
5. Locate the J1 and J3 connectors shown in
Figure 2.
6. Install the module by placing the module’s
connectors onto the controller card as
shown in Figure 3.
In order to avoid bending the connector
pins, exercise appropriate caution.
Make sure that the connection is secure.
7. Close the controller by snapping the plastic
Figure 1. Opening the Controller cover back in its place. If the card is placed
correctly, the cover will snap on easily.
8. If required, reinstall the Snap-in Module.
Module Port
installation location
position
Figure 3. Installing the Module
Figure 2. Controller, Main PCB Board
V200- 19- ET 1 3/05
Ethernet COM Port
Installation Instructions
1. Turn power off before opening the
controller.
2. If the controller has an installed Snap-in
I/O module, remove it. Instructions are
given in ‘Removing a Snap-in Module’ in
Slots
the Vision User Guide.
3. Open the OPLC by inserting a screwdriver
into the slots located on the sides of the
controller as shown, then carefully prying
the cover off.
4. The port’s location is covered by plastic.
Port, Remove the plastic covering using a razor
Tabs
covered cutter to cut through the tabs shown in
Figure 1.
5. Locate the J1 and J3 connectors shown in
Figure 2.
6. Install the module by placing the module’s
connectors onto the controller card as
shown in Figure 3.
In order to avoid bending the connector
pins, exercise appropriate caution.
Make sure that the connection is secure.
7. Close the controller by snapping the plastic
Figure 1. Opening the Controller cover back in its place. If the card is placed
correctly, the cover will snap on easily.
8. If required, reinstall the Snap-in Module.
Module Port
installation location
position
Figure 3. Installing the Module
Figure 2. Controller, Main PCB Board
COMMUNICATION PORT-1
V200-19-ET1 Ethernet COM Port
The V200-19-ET1 Ethernet COM Port is a communication module that enables you to install an Ethernet COM
port into compatible Vision controllers. The Ethernet port enables you to implement communications via
TCP/IP, such as MODBUS over TCP.
Before using this product, it is the responsibility of the user to read and understand this document
and any accompanying documentation.
All examples and diagrams shown herein are intended to aid understanding, and do not guarantee
operation. Unitronics accepts no responsibility for actual use of this product based on these
examples.
Please dispose of this product in accordance with local and national standards and regulations.
Only qualified service personnel should open this device or carry out repairs.
User safety and equipment protection guidelines
This document is intended to aid trained and competent personnel in the installation of this equipment as
defined by the European directives for machinery, low voltage, and EMC. Only a technician or engineer trained
in the local and national electrical standards should perform tasks associated with the device’s electrical wiring.
Symbol Meaning Description
Symbols are used to highlight
The identified danger causes physical
information relating to the user’s
Danger
and property damage.
personal safety and equipment
protection throughout this document. The identified danger can cause
Warning
When these symbols appear, the physical and property damage.
associated information must be read
carefully and understood fully. Caution Caution Use caution.
Failure to comply with appropriate safety guidelines can result in severe personal injury
or property damage. Always exercise proper caution when working with electrical
equipment.
Check the user program before running it.
Do not attempt to use this device with parameters that exceed permissible levels.
Install an external circuit breaker and take appropriate safety measures against short-
circuiting in external wiring.
The V200-19-ET1 Ethernet COM Port is a communication module that enables you to install an Ethernet COM
port into compatible Vision controllers. The Ethernet port enables you to implement communications via
TCP/IP, such as MODBUS over TCP.
Before using this product, it is the responsibility of the user to read and understand this document
and any accompanying documentation.
All examples and diagrams shown herein are intended to aid understanding, and do not guarantee
operation. Unitronics accepts no responsibility for actual use of this product based on these
examples.
Please dispose of this product in accordance with local and national standards and regulations.
Only qualified service personnel should open this device or carry out repairs.
User safety and equipment protection guidelines
This document is intended to aid trained and competent personnel in the installation of this equipment as
defined by the European directives for machinery, low voltage, and EMC. Only a technician or engineer trained
in the local and national electrical standards should perform tasks associated with the device’s electrical wiring.
Symbol Meaning Description
Symbols are used to highlight
The identified danger causes physical
information relating to the user’s
Danger
and property damage.
personal safety and equipment
protection throughout this document. The identified danger can cause
Warning
When these symbols appear, the physical and property damage.
associated information must be read
carefully and understood fully. Caution Caution Use caution.
Failure to comply with appropriate safety guidelines can result in severe personal injury
or property damage. Always exercise proper caution when working with electrical
equipment.
Check the user program before running it.
Do not attempt to use this device with parameters that exceed permissible levels.
Install an external circuit breaker and take appropriate safety measures against short-
circuiting in external wiring.
I/O-5
8 Digital pnp inputs, including 1 High-speed counter
8 Relay outputs
(This unit is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; EX-A1 adapter not required).
IO-DI8ACH
IO-DI8ACH
110/220 VAC
8 AC Inputs
IO-DI8-TO8-L
IO-DI8-TO8-L
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Transistor pnp outputs.
IO-DI8-RO8-L
IO-DI8-RO8-L
12VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Relay outputs.
IO-DI8-RO4-L
IO-DI8-RO4-L
12VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
4 Relay outputs.
IO-RO8
IO-RO8
24VDC (power supply)
8 Relay outputs.
IO-RO8-L
IO-RO8-L
12VDC (power supply)
8 Relay outputs.
IO-RO16-L
IO-RO16-L
12VDC (power supply)
16 Relay outputs.
IO-DI8ACH
IO-DI8ACH
110/220 VAC
8 AC Inputs
8 Relay outputs
(This unit is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; EX-A1 adapter not required).
IO-DI8ACH
IO-DI8ACH
110/220 VAC
8 AC Inputs
IO-DI8-TO8-L
IO-DI8-TO8-L
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Transistor pnp outputs.
IO-DI8-RO8-L
IO-DI8-RO8-L
12VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Relay outputs.
IO-DI8-RO4-L
IO-DI8-RO4-L
12VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
4 Relay outputs.
IO-RO8
IO-RO8
24VDC (power supply)
8 Relay outputs.
IO-RO8-L
IO-RO8-L
12VDC (power supply)
8 Relay outputs.
IO-RO16-L
IO-RO16-L
12VDC (power supply)
16 Relay outputs.
IO-DI8ACH
IO-DI8ACH
110/220 VAC
8 AC Inputs
I/O-4
8 Relay outputs
Adapter not required.
EX-D16A3-TO16
EX-D16A3-TO16
24VDC
16 Digital pnp/npn inputs, including 1 High-speed counter
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
16 Transistor pnp/npn outputs, including 1 High-speed output
Adapter not required.
IO-DI8-TO8
IO-DI8-TO8
24VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Transistor pnp outputs.
Supports Fast-response (in conjunction with Vision PLCs)
IO-DI8-RO8
IO-DI8-RO8
24VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Relay outputs.
IO-DI8-RO4
IO-DI8-RO4
24VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
4 Relay outputs.
IO-DI16
IO-DI16
24VDC
16 Digital pnp/npn inputs, including 1 High-speed counter.
IO-TO16
IO-TO16
12/24VDC
16 Transistor pnp outputs.
IO-RO8
IO-RO8
24VDC (power supply)
8 Relay outputs.
IO-RO16
IO-RO16
24VDC (power supply)
16 Relay outputs.
EX90-DI8-RO8
EX90-DI8-RO8
24VDC
Adapter not required.
EX-D16A3-TO16
EX-D16A3-TO16
24VDC
16 Digital pnp/npn inputs, including 1 High-speed counter
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
16 Transistor pnp/npn outputs, including 1 High-speed output
Adapter not required.
IO-DI8-TO8
IO-DI8-TO8
24VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Transistor pnp outputs.
Supports Fast-response (in conjunction with Vision PLCs)
IO-DI8-RO8
IO-DI8-RO8
24VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
8 Relay outputs.
IO-DI8-RO4
IO-DI8-RO4
24VDC
8 Digital pnp/npn inputs, including 1 High-speed counter
4 Relay outputs.
IO-DI16
IO-DI16
24VDC
16 Digital pnp/npn inputs, including 1 High-speed counter.
IO-TO16
IO-TO16
12/24VDC
16 Transistor pnp outputs.
IO-RO8
IO-RO8
24VDC (power supply)
8 Relay outputs.
IO-RO16
IO-RO16
24VDC (power supply)
16 Relay outputs.
EX90-DI8-RO8
EX90-DI8-RO8
24VDC
I/O-3
IO-PT4
IO-PT4
4 PT100 inputs, range: -50°C : 460°C (-58°F : 860°F), 12 bit.
IO-PT400
IO-PT400
4 PT100 / NI100 / NI120 inputs,
Range PT100: -50°C : 460°C (-58°F : 860°F)
Range NI100: -50°C : 232°C (-58°F : 449°F)
Range NI120: -50°C : 172°C (-58°F : 341°F)
12 bit.
IO-PT4K
IO-PT4K
4 PT1000 / NI1000 inputs
Range PT1000: -50oC ÷ 460oC, (-58oF ÷ 860oF)
Range NI1000: -50oC ÷ 232oC, (-58oF ÷ 449oF)
12 bit
IO-ATC8
IO-ATC8
8 Thermocouple/Analog inputs (T/C: J, K, T, B, E, N, R, S, 0.1° resolution. Analog: 12/14 bit, 0-10V, 0-20mA, 4-20mA).
IO-LC1
IO-LC1
12/24VDC (power supply)
1 Loadcell / Strain gauge input. Voltage range: ±20mV, ±80mV, execution: AC/DC
1 Digital pnp input
2 setpoint pnp outputs
(* Not supported by the M90 line).
IO-LC3
IO-LC3
12/24VDC (power supply)
3 Loadcell / Strain gauge inputs. Voltage range: ±20mV, ±80mV, execution: AC/DC
1 Digital pnp input
2 setpoint pnp outputs
(* Not supported by the M90 line).
IO-D16A3-RO16
IO-D16A3-RO16
24VDC
16 Digital pnp/npn inputs, including 2 High-speed counters
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
16 Relay outputs
3D View
IO-D16A3-TO16
IO-D16A3-TO16
24VDC
16 Digital pnp/npn inputs, including 1 High-speed counter
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
16 Transistor pnp/npn outputs, including 1 High-speed output
3D View
EX-D16A3-RO8
EX-D16A3-RO8
24VDC
16 Digital pnp/npn inputs, including 2 High-speed counters
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
IO-PT4
4 PT100 inputs, range: -50°C : 460°C (-58°F : 860°F), 12 bit.
IO-PT400
IO-PT400
4 PT100 / NI100 / NI120 inputs,
Range PT100: -50°C : 460°C (-58°F : 860°F)
Range NI100: -50°C : 232°C (-58°F : 449°F)
Range NI120: -50°C : 172°C (-58°F : 341°F)
12 bit.
IO-PT4K
IO-PT4K
4 PT1000 / NI1000 inputs
Range PT1000: -50oC ÷ 460oC, (-58oF ÷ 860oF)
Range NI1000: -50oC ÷ 232oC, (-58oF ÷ 449oF)
12 bit
IO-ATC8
IO-ATC8
8 Thermocouple/Analog inputs (T/C: J, K, T, B, E, N, R, S, 0.1° resolution. Analog: 12/14 bit, 0-10V, 0-20mA, 4-20mA).
IO-LC1
IO-LC1
12/24VDC (power supply)
1 Loadcell / Strain gauge input. Voltage range: ±20mV, ±80mV, execution: AC/DC
1 Digital pnp input
2 setpoint pnp outputs
(* Not supported by the M90 line).
IO-LC3
IO-LC3
12/24VDC (power supply)
3 Loadcell / Strain gauge inputs. Voltage range: ±20mV, ±80mV, execution: AC/DC
1 Digital pnp input
2 setpoint pnp outputs
(* Not supported by the M90 line).
IO-D16A3-RO16
IO-D16A3-RO16
24VDC
16 Digital pnp/npn inputs, including 2 High-speed counters
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
16 Relay outputs
3D View
IO-D16A3-TO16
IO-D16A3-TO16
24VDC
16 Digital pnp/npn inputs, including 1 High-speed counter
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
16 Transistor pnp/npn outputs, including 1 High-speed output
3D View
EX-D16A3-RO8
EX-D16A3-RO8
24VDC
16 Digital pnp/npn inputs, including 2 High-speed counters
3 Analog inputs, 10 bit, 0-20mA, 4-20mA
Subscribe to:
Posts (Atom)